Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps

Product Details
Customization: Available
Media: Water
Certification: CE
Still deciding? Get samples of US$ 50/Piece
Request Sample
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
100% Finished Products Inspection
The supplier inspects 100% of finished products.
R&D Capabilities
The supplier has 2 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (13)
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
  • Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
Find Similar Products
  • Overview
  • Detailed Photos
  • Product Description
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
HC-Y010
Temperature
Ordinary Temperature
Connection
Flange
Material
Stainless Steel
Product Name
Inverted-Cylinder Steam Trap
Normal Pressure
1.6MPa
Warranty
1 Year
Valve Body, Valve Deck
Ht200
Port Size
DN15-200
Temperature of Media
High Temperature, Low Temperature, Medium Temperat
Power
Manual
Transport Package
Carton
Specification
3kg
Trademark
HC
Origin
Fujian, China
HS Code
8481804090
Production Capacity
1000/Pieces Per Month

Product Description

Detailed Photos
Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam TrapsPilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam TrapsPilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam TrapsPilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam TrapsPilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam TrapsPilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
 
  
Product Description
 
Shell pressure rating Load leakage rate Use medium Allowable back pressure rate Energy-saving effect Suitable superheated steam
1.6,2.5,4.0,6.4,10MPa 0% Steam, condensate 75% excellence Adaption
Maximum working pressure difference Frost resistance Drainage mode Maximum permissible temperature Air exhaust device resist
10.0MPa excellence Continuous mode 420~550ºC automatic Adaption
Packaging & Shipping
Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
Company Profile
Pilot-Operated Tap Water Pressure Reducing Valve Adjustable Fire Hydraulic Control Valve Tlv Steam Traps
Heng cheng trap company is a manufacturer specializing in production steam trap,Production of steam and air inverted drum, rod and rod float, temperature difference, free float, bi metal Plate steam, high temperature and pressure bi metal, thermostatic (bellows),thermostatic (diaphragm box), disc (thermodynamic), steam-water separator and other traps.This product can save a lot of energy consumption, improve work efficiency, reduce costs, save energy and protect the environment.
Our products have been widely used in petroleum, chemical industry,metallurgy, electric,paper making, printing and dyeing, food engineering equipment and industrial equipment and pipe, favored by majority of users trust and praise! In the current fierce market competition,our company provide high-quality products, perfect after-sales service and competitive price. 

 
FAQ

(1)Q: How does a steam trap work?
A: The trap opens and closes automatically based on the pressure difference of the fluid. When the pressure in a pipe or equipment exceeds a preset limit, the trap opens, allowing water or condensate to drain from the system; when the pressure drops below the set value, the trap closes, preventing fluid from the system. drain.

(2)Q: What is the main purpose of a steam trap?
A: Traps are mainly used to remove condensation water from pipes or equipment to avoid damage to the system. They are usually widely used in steam systems, air compressors, cooling towers and other industrial equipment.

(3)Q: What are the common types of steam traps?
A: Common trap types include float traps, funnel traps, instantaneous traps and turbine traps, etc. Each type of trap has its own characteristics and scope of application.

(4)Q: How to choose a suitable trap?
A: When choosing a suitable trap, you need to consider factors such as the operating pressure, flow rate, media type and temperature of the system. In addition, the appropriate trap must be selected based on the size and installation requirements of the equipment.

(5)Q: How to maintain and maintain steam traps?
A: Maintenance and maintenance of steam traps include regular inspection, cleaning and lubrication. Regular inspections can ensure that traps are functioning properly and avoid clogging. Cleaning and lubrication can extend the life of your trap and improve its performance.

(6)Q: Do steam traps need to be replaced regularly?
A: Yes, steam traps typically require periodic replacement to ensure they operate effectively. Depending on usage and manufacturer's recommendations, it is generally recommended to replace traps annually or more frequently.

(7)Q: What are the common failures and solutions for steam traps?
A: Common trap failures include water leakage, blockage, and failure to open. Solutions to these problems may include cleaning, replacing the seals, or replacing the entire trap.

(8)Q: Can the trap be installed by myself?
A: The installation of steam traps usually requires professionals because factors such as the installation location of the pipe, flow direction, and fluid characteristics need to be considered. If you do not have the relevant knowledge and skills, it is best to ask professionals to install it.

 